S13 Oil Immersed Hermetically Sealed Distribution Transformer
Performance Characteristics
●Compared with S11 type transformer, the no-load loss of this series is reduced by about 30% on average.
●Capacity in the range of 630~2000kVA low-voltage winding adopts cylinder or spiral structure, high mechanical strength, ampere-turn distribution balance, the product of short-circuit resistance is good.
The short-circuit resistance of the product is good.
●The body of the product is equipped with additional positioning structure so that it does not shift during transportation, and all the fasteners are equipped with fastening nuts to ensure that the fasteners do not loosen during long-term operation.
●Meanwhile, all fasteners are equipped with fastening nuts to ensure that the fasteners will not loosen during long-term operation, which meets the requirement of not lifting the core.
●The transformer adopts corrugated oil tank, eliminating the oil storage cabinet, and the cover and the edge of the tank are completely welded or bolted, prolonging the service life of the transformer oil.
●The surface of the product is degreased, descaled, phosphatized and then sprayed with primer and top coating, which can meet the special requirements of metallurgy, petrochemical system and humid and dirty areas.
The products can meet the special requirements of metallurgical and petrochemical systems and humid and dirty areas.
●Selected components, fully sealed transformer tanks, pressure relief valves, signal thermometers, gas relays, etc. are installed according to standard requirements to ensure the safe operation of the transformer.
This series of products has a beautiful appearance and small volume, ensuring the safe operation of the transformer.
●This series of products have beautiful appearance, small volume, can reduce the installation area, is the ideal maintenance-free high-quality products.
Implementation standards
●GB1094.1~2-2013 Power Transformer
●GB1094.3,5-2003 Power Transformer
●GB1094.4-2005 power transformer
●GB/T6451-2015 three-phase oil-immersed power transformer technical parameters and requirements
Model Number and Meaning
Model Number S13-M-□/□
S | 13 | M | □ | □ |
Three phase oil immersed transformer | Performance level code | Sealed construction | Rated capacity(KVA) | Voltage level(KV) |
Technical parameter
Rated capacity (KVA) | voltage combination | Connection group label | No-load loss (W) | load loss (W) | Short circuit resistance (%) | No-load current (%) | Weight(Kg) | External dimensions | Gauge (mm) | ||||
High tension (KV) | Tapoff (%) | Low pressure (KV) | Body weight | Oil weight | Total weight | L×W×H | |||||||
30 | 6 6.3 10 10.5 11 | ±5% or ±2×2.5% | 0.4 0.415 0.422 0.433 | Yyn0 or Dyn11 | 80 | 600/630 | 4.0 | 2.1 | 200 | 65 | 325 | 700×555×870 | 400×400 |
50 | 100 | 870/910 | 2 | 215 | 100 | 420 | 820×660×935 | 400×400 | |||||
63 | 110 | 1040/1090 | 1.9 | 260 | 110 | 460 | 850×660×950 | 450×450 | |||||
80 | 130 | 1250/1310 | 1.8 | 310 | 120 | 540 | 870×665×970 | 500×500 | |||||
100 | 150 | 1500/1580 | 1.6 | 350 | 145 | 620 | 880×670×1010 | 500×500 | |||||
125 | 170 | 1800/1890 | 1.5 | 415 | 170 | 710 | 930×690×1040 | 500×500 | |||||
160 | 200 | 2200/2310 | 1.4 | 485 | 180 | 830 | 865×765×1050 | 550×550 | |||||
200 | 240 | 2600/2730 | 1.3 | 540 | 185 | 990 | 1200×770×1070 | 550×550 | |||||
250 | 290 | 3050/3200 | 1.2 | 640 | 190 | 1130 | 1270×830×1120 | 550× 550 | |||||
315 | 340 | 3650/3830 | 1.1 | 750 | 230 | 1330 | 1420×960×1190 | 550× 550 | |||||
400 | 410 | 4300/4520 | 1.0 | 900 | 260 | 1560 | 1420×960×1220 | 660×660 | |||||
500 | 480 | 5150/5410 | 1.0 | 1040 | 300 | 1800 | 1500×1010×1275 | 660×660 | |||||
630 | 570 | 6200 | 4.5 | 0.9 | 1250 | 380 | 2125 | 1650×1140×1350 | 660×660 | ||||
800 | 700 | 7500 | 0.8 | 1470 | 440 | 2490 | 1750×1200×1510 | 820×820 | |||||
1000 | 830 | 10300 | 0.7 | 1720 | 500 | 2900 | 1780×1260×1550 | 820×820 | |||||
1250 | 970 | 12000 | 0.6 | 1860 | 580 | 3580 | 1860×1300×1610 | 820×820 | |||||
1600 | 1170 | 14500 | 0.6 | 2280 | 730 | 4070 | 1940×1360×1660 | 820×820 | |||||
2000 | 1550 | 18300 | Please contact us for detailed data. | ||||||||||
2500 | 1830 | 21200 |
Note:
1. The load loss value below the slash in the table applies to the products of the Dyn11 connection group.
2. For the technical parameters of the larger capacity 10kV class distribution transformer, the external size and weight data, please consult our company.
3.Transformer with various voltage combination, short-circuit impedance and connection mode can be provided according to user needs.