Hermetically Sealed Oil Filled Amorphous Alloy Distribution Transformer

Fully-sealed oil-immersed amorphous alloy transformers are a type of fully-sealed oil-immersed distribution transformers with amorphous alloy cores and magnetic conductive materials.
It is a fully sealed oil-immersed distribution transformer with an amorphous alloy core as the magnetic conductive material. It is an ideal electrical product for environmental protection and energy saving.
It is an ideal electrical product for environmental protection and energy conservation, and is in line with the spirit of China’s Energy Conservation Technology Outline promulgated by the State Economic Commission and the Planning Commission.
It is an ideal electrical product for environmental protection and energy conservation, which is in line with the spirit of “China Energy Conservation Technology Outline” issued by National Economic Commission and Planning Commission. In the past twenty years, it has been widely operated in the domestic and foreign power grids,
In the past twenty years, it has been widely operated in domestic and foreign power grids.


  • Product Code: S(B)H15

Performance Characteristics

●the core of the magnetic conductive material using amorphous alloy, amorphous alloy is iron, boron and other elements as raw materials, with rapid cooling and other special processes, spray casting into a band-like sheet, so that the atomic arrangement of the substance presents a disordered alloy. Because amorphous alloy has soft magnetic properties, hysteresis loop area is very narrow, that is, it only needs a very small magnetization chemical rate, so with amorphous alloy material made of transformer, its no-load loss is also very small.
●transformer core using amorphous alloy strip generally rolled into three-phase five-column structure, so that the height of the transformer than three-phase five-column low. Core cross-section is rectangular, its lower yoke can be opened to facilitate the coil set.
●low voltage winding in addition to small capacity using copper wire, generally use copper foil winding cylindrical structure; High voltage winding using multi-layer cylindrical structure, so that the winding of ampere-turn enactment balance, magnetic leakage is small. High and low voltage coils are wound together with wire tensioning device, and the whole process of press-fitting enhances the strength and short-circuit resistance.
●body assembly, oil tank structure, protection devices and other aspects of similar fully sealed oil-immersed distribution transformer, the same is the use of non-suspension structure, the use of vacuum drying, vacuum oil filtration and oil injection process, the use of corrugated oil tanks, there is no oil storage cabinets and other structures.
●the transformer load loss and S9 series load loss is the same, however, no-load loss SBH11 series than S9 series down 75% or so: SBH15 series than S9 series down 80% or so, through the annual power loss, the annual electricity saving cost calculation, generally in four years it can be recovered relative to the silicon steel sheet core transformer increased investment costs.

Structural characteristics

●Altitude not exceeding 1000m indoor or outdoor
●Maximum ambient air temperature +40 ℃ maximum average daily temperature +30 ℃
●Maximum annual average temperature +20 ℃ minimum air temperature -25 ℃ (according to user requirements can be provided in special conditions of operation of the transformer)

Implementation standards

CB1094.1~2-2013,GB1094.3.5-1995 Power Transformer
JB/T10318-2002 oil-immersed amorphous gold core power distribution transformer technical parameters and requirements

Model Number and Meaning

Model Number S(B)H□-M-□/□□

SBHM
Three-phaseLow Voltage Foil CoilAmorphous alloy corePerformance level code (11,15)Fully SealedRated capacity (kVA)High-voltage coil voltage class (kV)Special Use Environment

Technical Parameters

Rated capacity
(KVA)
Voltage combinationConnection group labelNo-load loss
(W)
load loss
(W)
Short circuit resistance  
(%)
No-load current
(%)
Weight(Kg)Gauge
(mm)
High tension
(KV)
Tapoff
(%)
Low pressure
(KV)
Oil weightTotal weight
306.3
  10
10.5
  11
±2×25%0.4Dyn11336004.01.7110410400×400
50438701.3140680400×400
635010401.2150720400×400
806012501.1160770400×550
1007515001.0190890400×550
1258518000.9210930400×550
16010022000.72901170550×870
20012026000.72701230550×870
25014030500.73001400550×870
31517036500.53101540550×870
40020043000.53601720660×1070
50024051500.53552000660×1070
63032062004.50.34402400660×1070
80038075000.36302950660×1070
1000450103000.36803500660×1070
1250530120000.27904100660×1070
1600630145000.211005550660×1070
2000750174005.00.213106150850×1075
2500900202000.2199066001070×1475

Note: The weight and external dimension data in the table are for reference only and are subject to change without notice.