3-Phase Dry Type Transformer Class H Insulation

This product is a high performance, high safety, environmentally friendly dry-type transformer independently developed by our company with reference to the German MORA technology.
This product is a high performance, high safety and environmental protection dry-type transformer developed by our company with reference to German MORA technology.
It is suitable for high fire protection requirements, large load fluctuation and dirty and humid environment. For example, it can be used in airports, power plants, metallurgical plants, and other industries:
Airport, power plant, metallurgical operations, hospitals, high-rise buildings, shopping centers, densely populated areas and other places.
In special environments such as airports, power plants, metallurgical operations, hospitals, high-rise buildings, shopping centers, densely populated areas, and oil and chemical plants, nuclear power stations, and nuclear submarines.
Special environments


  • Product Code: SG(H)B10-100~2500/10

Performance Characteristics

Good heat dissipation conditions, long thermal life, excellent overload capacity. In 120% long-term overload, IP45 conditions without forced air cooling, can be long-term full-load operation. -Extremely high safety and flame retardant performance, no smoke generation under 800℃ high temperature and long time burning.
-Extremely strong resistance to thermal shock (can be immediately added to the full load at -50 ℃).
-100% waterproof sealing, excellent waterproof and moisture resistance.
-Unique coil structure and strong field calculation, so that the product is almost no local discharge generation.
-Low loss, remarkable energy saving effect.
-Insulation materials and copper wires can be easily separated and recycled after the life span, without polluting the environment.

Implementation standards

-GB1094.11-2007 Dry-type power transformer
GB/T10228-2015 Technical parameters and requirements for dry-type power transformers
-GBT17211-1998 dry-type power transformer load guidelines
-GB1094.3-2003 power transformer part 3: insulation level, insulation test and outer insulation air gap
-JB/T10088-20076~500kV transformer sound level
JB/T56009-1998 Product quality classification of dry-type power transformer.

Model Number and Meaning

Model Number : SG(H)B10-□/□

SG(H)B10
Three-phase transformersDry, air self-coolingInsulation classfoil-wound coilPerformance Level DesignatorRated capacity (kVA)Voltage level (kV)

Structural characteristics

Unique porcelain insulation structure with H-class high-strength insulating cylinder and high-frequency ceramic pads, never deformed. -High and low voltage coils are made of NOMEX paper-wrapped flat copper wires and imported copper foils, and vacuumed by VPI.

Technical parameter

Rated capacity
(KVA)
voltage combinationConnection group labelNo-load loss
(W)
load loss(W)
120℃
No-load current
(A)
Short circuit resistance  
(%)
Host machine weight
(Kg)
External dimensions(mm)Gauge
(mm)
High tension
(KV)
Tapoff
(%)
Low pressure
(KV)
L×W×H
(No protective cover)
L×W×H
(No protective cover)
1006
6.3
6.6
10
10.5
11
±2
X2.5%
or
±3
X2.5%
0.4
0.415
0.422
0.433
Yyn0
or
Dyn11
41021701.84.07301030×600×10151300×1000×1300550×550
12548025901.68201050×600×10551350×1000×1325550×550
16054031001.59201080×600×10551390×1000×1400550×550
20062039801.410301110×600×10551410×1000×1450   550×550
25072046751.412101130×710×11151430×1010×1510   660×660
31588056101.213801270×710×12401770×1210×1695 660×660
40098066301.216501315×710×13001815×1210×1695 660×660
500116079501.218901230×870×12601910×1210×1800 660×820
630134092551.0 19101540×710×14701990×1210×1745   660×660
630133097751.0 6.020001490×710×13501990×1210×1745660×660
8001520115601.0 22801520×870×14102020×1370×1710820×820
10001770133451.0 26001590×870×14602090×1310×1860820×820
12502090156401.0 31001720×1010×15752220×1510×1970820×960
16002650181051.0 36501780×1120×17452280×1620×2140820×1070
20003050212500.844001850×1120×18102320×1750×22601070×1070
25003600243750.852001950×1120×19102360×1800×23001070×1070

Note: The weight and external dimension data in the table are for reference only and are subject to change without notice.